Post Buying Request
6F22 9V
6F22 9V

Trading Company,Manufacturer

  • Product Details
  • Company Profile

6F22 9V

Product description

1.Scope

This specification governs the technical requirements of Daily-max Carbon Zinc battery of 6F22. If it doesn’t list the other detailed requirements, the technical requirements and dimensions of battery should meet or above GB/T8897.1-2008 and GB /T8897.2-2013.

1.1Reference Document

GB/T8897.1 (IEC60086-1,MOD)(Primary Battery Part 1: General)

GB/T8897.2 (IEC60086-2,MOD)(Primary Battery Part 2: Dimensions and Technical Requirements)

GB8897.5 (IEC 60086-5,MOD)(Primary Battery Part 5: aqueous electrolyte battery safety requirements)

1.2Environmental protection standard

The battery accord with 2006/66/EC

2.Chemical system, Voltage and Designation

Electrochemical system: zinc - manganese dioxide (ammonium chloride electrolyte  solution), does not contain mercury

Nominal voltage:1.5V

Naming :IEC:6F22    JIS:006P    

3.Battery Size

Conform to the requirements of the brief

电池符合简图要求

 

3.1 Acceptance tool

Using vernier caliper measurement precision is not less than 0.02 mm, measure to prevent the battery short circuit, one end of the caliper head card should be labeled as a layer of insulating materials。

3.2 Acceptance methods

The GB2828.1-2003 normal inspection sampling plan at a time,special inspection level S-3,acceptance quality limit AQL=1.0

4.Weight and discharging capacity

Typical Weight: 36g

discharge capacity:150mAh(load 180Ω, 24h/day, 20±2℃,RH60±15%, final 

voltage 4.8V)

 

5.open-circuit voltage、closed - circuit voltage and short-circuit current

items

OCV(V)

sampling standard

After 2 months, new battery

10.0~10.3

GB2828.1-2003 Normal inspection sampling plan, special inspection level S-4,AQL=1.0

After 12 months at
room temperature

9.8~10.0

Test conditions

load resistance 3.9Ω, measuring time 0.3 seconds,temperature 20±2℃

6.Discharging Ability

temperature:20±2℃

Discharge Conditions

GB/T8897.2-2008
National standard requirement

Shortest Average
Discharging Time

Discharge load

Discharge Time

Cut-off discharge voltage


After 2 months, new battery

After 12 months at
room temperature

620Ω

2h/d

5.4 V

26h

26h

23.4h

270Ω

1h/d

5.4 V

8h

8h

7.2h

180Ω

24h/d

4.8 V

/

3.5h

3.1h

Satisfaction Standard:

1)9 pieces of battery will be tested for each discharging standard;

2)The result of the average discharging time from each discharging standard shall be equal to or more than the average minimum time requirement; no more than one battery has a service output less than 80% of the specified requirement. Then the batch battery performance test qualified.

3)If nine section of the battery discharge average less than the specified value of minimum average discharge time and (or) is less than the specified value of 80% of the battery number more than 1,we should take another 9 batteries to test again and calculate the average. Calculation results conform to the requirement of article 2, the batch battery performance test qualified. If it does not conform to the requirement of article 2, the batch battery performance test is unqualified, and no longer test.

 

7.Anti-leakage ability

Discharge Conditions

requirement

Acceptance Standard

Environmental
conditions

Discharge load
(Ω)

Discharge Time

Cut-off discharge voltage(V)

at temperature 20±2℃; relative humidity: 60±15% RH

620

2h/d

3.6

 No leakage recognized by eyes

N=9
Ac=0
Re=1

270

1h/d

180

24h/d

8.Safety Characteristics

items

Condition

Requirement

Acceptance Standard

External short circuit

At temperature 20±2℃,With wires to the battery positive negative switched on 24 hours

No explosion
allowed

N=5
Ac=0
Re=1

9.Signs

The following markings will be printed, stamped or impressed on the body of battery:

1.Designation: 6F22

2.Manufacturer or trademark:Daily-max

3.Polarity:“+”and“-”

4.Expiration date deadline or manufacturing time

5.The attention notes for safe use.

10. Cautions for Use

1.Since the battery is not manufactured for recharging, there are risks of electrolyte leakage or causing damage to the device if the battery is charged.

2.The battery shall be installed with its “+” and “-” polarity in a correct position, otherwise may cause short-circuit.

3.Short-circuiting, heating, disposing of into fire or disassembling of battery is prohibited.

4.Battery can not be forced discharged, which leads to excess gassing and may result in bulging, leakage and de-crimping of cap.

5.New batteries and used ones can not be used at the same time. It is recommended to use the same brand when replacing batteries.

6.Electrical appliances should be take out the battery when not in use for a long time

7.Exhausted batteries shall be removed from the compartment in order to prevent over-discharge.

8.Prohibit direct welding battery, otherwise it will damage the battery.

9.Battery are to be kept away from children. If swallowed, contact a physician at once.

 

11.Normal Packing

Every 2 or 3 and 4 batteries or according to customer requirements with 

transparent membrane after hot shrinkage, each 60 knots in 1 inner boxes, 

20 boxes into 1 box.

12.Storage and shelf life

1.Batteries should be stored in ventilated, cool and dry place。

2.The battery should not be exposed to direct sunlight for a long time or in the rain。

3.Not to mix removed packaging battery stack together

4.Stored at condition of tempreture20℃±2℃, relative humidity 60±15%RH, the battery shelf life is 2 years。

13. Typical discharge curve

Discharge environment:20℃±2℃,RH60±15%

With parameter adjustment, product technology updates, technology specification will update at any time, please do not hesitate to contact to stand for the latest version of the specification.


Send Inquiry to This Supplier

  • Title
  • From*
  • to
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x